 ALTER LINE Command
 corresponds to the SYSGEN modifier CLBSTATUSPROBETIME. ZTEST-
 INTVL is valid only for line handlers that are configured as
 HDLC Normal for 6100 CSS.
 ZTHRES specifies the number of frames that must be sent
 and received before line quality is checked. This value
 must be in the range 100 through 16384, and the default
 value is 500. This field corresponds to the SYSGEN modifier
 LINEQUALITYTHRESHOLD. ZTHRES is valid only for line handlers
 that are configured as HDLC Normal for 6100 CSS or the
 multifunction controller.
 ZTIMEOUT specifies the amount of time in microseconds that
 the level-2 T1 timer will run before timing out. This value
 must be in the range 0 through 327,670,000. The default
 value is 2,000,000 for line handlers that are configured
 as HDLC Extended for bit-synchronous and byte-synchronous
 transmission, 0 for NETNAM line handlers, and 1,000,000 for
 other types of line handlers. This field corresponds to the
 SYSGEN modifier L2TIMEOUT. ZTIMEOUT is valid for all types of
 line handlers.
 ZTIMER-BIND specifies the amount of time in microseconds that
 the line handler will wait for successful completion of the
 bind to the NET subdevice. The default value is 60,000,000
 for NETCLUSTER (FOX) lines and 30,000,000 for NETNAM (X.25)
 lines. A value of 0 indicates an indefinite interval. This
 field corresponds to the SYSGEN modifier TIMERBIND. ZTIMER-
 BIND is valid only for NAM line handlers.
 ZTIMER-INACTV specifies the amount of time in microseconds the
 line handler will remain inactive before it requests that the
 network service provided by the NAM be disconnected. This
 value must be in the range 0 through 32,767,000,000. The
 default value is 0 for NETCLUSTER (FOX) lines and 900,000,000
 for NETNAM (X.25) lines. A value of 0 indicates an indefinite
 interval. This field corresponds to the SYSGEN modifier
 TIMERINACTIVITY. ZTIMER-INACTV is valid only for NAM line
 handlers.
 ZTIMER-PROBE specifies the amount of time in microseconds
 for the line handler to obtain the status of the NAM. The
 default value is 30,000,000 for NETCLUSTER (FOX) lines and
 300,000,000 for NETNAM (X.25) lines. A value of 0 indicates
 an indefinite interval. This field corresponds to the SYSGEN
 modifier TIMERPROBE. ZTIMER-PROBE is valid only for NAM line
 handlers.
 ZTIMER-RECONN specifies the amount of time in microseconds for
 the line handler to wait to successfully initiate a network
 connection. The default value is 60,000,000 for NETCLUSTER
 (FOX) lines and 30,000,000 for NETNAM (X.25) lines. A value
 of 0 indicates an indefinite interval. This field corresponds
 7-16