Expand Management Programming Manual
COMMANDS AND RESPONSES
ALTER LINE Command
corresponds to the SYSGEN modifier CLBSTATUSPROBETIME. ZTEST-
INTVL is valid only for line handlers that are configured as
HDLC Normal for 6100 CSS.
ZTHRES specifies the number of frames that must be sent
and received before line quality is checked. This value
must be in the range 100 through 16384, and the default
value is 500. This field corresponds to the SYSGEN modifier
LINEQUALITYTHRESHOLD. ZTHRES is valid only for line handlers
that are configured as HDLC Normal for 6100 CSS or the
multifunction controller.
ZTIMEOUT specifies the amount of time in microseconds that
the level-2 T1 timer will run before timing out. This value
must be in the range 0 through 327,670,000. The default
value is 2,000,000 for line handlers that are configured
as HDLC Extended for bit-synchronous and byte-synchronous
transmission, 0 for NETNAM line handlers, and 1,000,000 for
other types of line handlers. This field corresponds to the
SYSGEN modifier L2TIMEOUT. ZTIMEOUT is valid for all types of
line handlers.
ZTIMER-BIND specifies the amount of time in microseconds that
the line handler will wait for successful completion of the
bind to the NET subdevice. The default value is 60,000,000
for NETCLUSTER (FOX) lines and 30,000,000 for NETNAM (X.25)
lines. A value of 0 indicates an indefinite interval. This
field corresponds to the SYSGEN modifier TIMERBIND. ZTIMER-
BIND is valid only for NAM line handlers.
ZTIMER-INACTV specifies the amount of time in microseconds the
line handler will remain inactive before it requests that the
network service provided by the NAM be disconnected. This
value must be in the range 0 through 32,767,000,000. The
default value is 0 for NETCLUSTER (FOX) lines and 900,000,000
for NETNAM (X.25) lines. A value of 0 indicates an indefinite
interval. This field corresponds to the SYSGEN modifier
TIMERINACTIVITY. ZTIMER-INACTV is valid only for NAM line
handlers.
ZTIMER-PROBE specifies the amount of time in microseconds
for the line handler to obtain the status of the NAM. The
default value is 30,000,000 for NETCLUSTER (FOX) lines and
300,000,000 for NETNAM (X.25) lines. A value of 0 indicates
an indefinite interval. This field corresponds to the SYSGEN
modifier TIMERPROBE. ZTIMER-PROBE is valid only for NAM line
handlers.
ZTIMER-RECONN specifies the amount of time in microseconds for
the line handler to wait to successfully initiate a network
connection. The default value is 60,000,000 for NETCLUSTER
(FOX) lines and 30,000,000 for NETNAM (X.25) lines. A value
of 0 indicates an indefinite interval. This field corresponds
7-16