position ID. A character that indicates the position an HP NonStop™ Cluster Switch 
occupies in a network topology. The position ID is a component of the two-character 
cluster switch name. The cluster switch name includes an external fabric ID (X or Y) as 
the first character and a position ID as the second character. For example, the cluster 
switch name X3 indicates that the cluster switch serves the external ServerNet X fabric 
and occupies position 3 in the topology. Supported values for position IDs are 1 
through 9 or A through Z. Currently supported topologies (star, split-star, and tri-star) 
use position IDs 1, 2, and 3. 
position-independent code (PIC). Executable program or library code that is designed to 
be loaded and executed at any virtual memory address, without any modification. 
Addresses that can be modified by the loader do not appear in PIC code, only in data 
that can be modified by the loader. See also dynamic-link library (DLL).
POSIX. The Portable Operating System Interface, as defined by the Institute of Electrical 
and Electronics Engineers (IEEE) and the American National Standards Institute 
(ANSI).  Each POSIX interface is separately defined in a numbered ANSI/IEEE 
standard or draft standard. The application program interface (API), known as 
POSIX.1, has become ISO/IEC IS 9945-1:1990.
power distribution panel (PDP). A group of panel assemblies that composes a single 
panel that includes buses and overcurrent protection devices (with or without 
switches). A PDP is used for the control of power circuits.
power distribution unit (PDU). See computer-room power center (CRPC).
power domain. A set of customer-replaceable units (CRUs) and field-replaceable units 
(FRUs) that share a set of power rails. For Telco Central Office (CO) systems, the 
power domain is the entire system.
power factor. The ratio of real power to apparent power (that is, kilowatts/kilovoltamperes). 
The power factor for a sinusoidal load is determined by the position of the applied 
voltage waveform with respect to the current drawn by the load. When voltage and 
current are in phase with each other, the power factor is unity and the power for the 
load is equal to the product of the applied voltage and load current (P=EI). When the 
current waveform lags after the voltage waveform, the load is inductive. Conversely, 
when the current waveform leads the voltage waveform, the load is capacitive. In either 
case, the power for the load is equal to the product of the applied voltage, load current, 
and the angular displacement between the voltage and current waveforms (P=EIcosf). 
Nonlinear (nonsinusoidal) loads also have a power factor; however, the power factor 
for a nonsinusoidal load reflects harmonic content and not angular displacement.