Fast Ethernet Adapter Installation and Support Guide
Replacing an FESA
Fast Ethernet Adapter Installation and Support Guide—425685-003
3-22
Remove the Adapter
Remove the Adapter
The following describes how to remove the adapter.
1. Disconnect the communications cables from the FESA.
2. Put on your electrostatic discharge (ESD) wriststrap and connect the grounding clip
securely to an exposed, unpainted, metal surface on the service side of the system
enclosure, such as the processor multifunction (PMF) CRU or I/O multifunction
(IOMF) CRU ventilation holes
The figure shows how to connect the grounding clip to the ventilation holes on the
PMF or IOMF CRU.
3. Unlatch the ejector on the FESA by pressing the blue-green tab on the ejector and
pulling the ejector outward to unseat the FESA from the backplane.
4. Grasp the FESA by its ejector in one hand and slowly pull the FESA out of the slot
while supporting the bottom edge of the FESA with the other hand.
Figure 3-4. Grounding Clip
Note. The FESA weighs 6.75 pounds (3 kilograms).
081CDT .CDD
Processor Multifunction (PMF) CRU or
I/O Multifunction (IOMF) CRU
Grounding
Clip
To Grounding
Wriststrap