Fast Ethernet Adapter Installation and Support Guide

Replacing an FESA
Fast Ethernet Adapter Installation and Support Guide425685-003
3-34
Verify that the Communications Lines are Restarted
5. Start the ServerNet wide area network (SWAN) concentrator and its associated
WAN subsystem IOPs and communications lines:
a. Start the SWAN concentrator.
Use the SCF START ADAPTER command with the SUB ALL option:
START ADAPTER $ZZWAN.#adapter-name, SUB ALL
b. Start the WAN subsystem IOPs.
Use the SCF START DEVICE command:
START DEVICE $ZZWAN.#device-name
c. Start the line(s).
1. Use the SCF START LINE command to start a single line:
START LINE $line-name
2. Use the SCF START PATH command to start all the lines in an Expand
multiline path:
START PATH $path-name
Verify that the Communications Lines are Restarted
Verify that communications lines using an FESA are started:
1. Verify that the TCP/IP subnet is started.
Use the SCF STATUS SUBNET command:
STATUS SUBNET $tcpip-process-name.#subnet-name
Example 3-29 shows the output of this command. Note that the subnet (#SN2)
is in the STARTED state.
Note. To verify a TCP/IP subnet that is configured using Parallel Library TCP/IP, refer to the
TCP/IP (Parallel Library) Configuration and Management Manual. To verify a TCP/IP subnet
that is configured using NonStop TCP/IPv6, refer to the TCP/IPv6 Configuration and
Management Manual.
Example 3-29. SCF STATUS SUBNET Command
->STATUS SUBNET $ZTC01.#SN2
TCPIP Status SUBNET \COWBOY.$ZTC01.#SN2
Name Status
#SN2 STARTED