Fast Ethernet Adapter Installation and Support Guide
Replacing an FESA
Fast Ethernet Adapter Installation and Support Guide—425685-003
3-36
Verify that the Communications Lines are Restarted
2. Use the SCF STATUS PATH command for an Expand multiline path:
STATUS PATH $path-name
Example 3-33 shows the output of this command. Note that the path is in
the STARTED state.
5. Verify that the ServerNet wide area network (SWAN) concentrator and its
associated WAN subsystem IOPs communications lines are started:
a. Verify that the SWAN concentrator is in the STARTED state.
Use the SCF STATUS ADAPTER with the SUB ALL option. The SUB ALL
option displays status information for the ADAPTER object and its
subordinate objects.
STATUS ADAPTER $ZZWAN.#adapter-name, SUB ALL
Example 3-34 on page 3-37 shows the output of this command. Note that
the ADAPTER, SERVER, PATH, and TASK objects are in the STARTED
state.
Example 3-32. SCF STATUS LINE Command
->STATUS LINE $LINE1
EXPAND Status LINE1
Name State PPID BPID CIU-Path ConMgr-LDEV
$SATHO0 STARTED 2, 10 3, 7 A 91
Example 3-33. SCF STATUS PATH Command
->STATUS PATH $PATH
EXPAND Status PATH
Name State PPID BPID Lines #
$PSHOT STARTED 2, 15 3, 15 2
Note. Detailed information for only one communications line interface processor