Fast Ethernet Adapter Installation and Support Guide
Replacing an FESA
Fast Ethernet Adapter Installation and Support Guide—425685-003
3-38
Verify that the Communications Lines are Restarted
c. Verify that the lines are in the STARTED state.
1. Use the SCF STATUS LINE command for a single line:
 STATUS LINE $line-name
Example 3-36 shows the output of these commands. Note that the line is in 
the STARTED state.
2. Use the SCF STATUS PATH command for an Expand multiline path:
STATUS PATH $path-name
Example 3-37 shows the output of these commands. Note that the path is 
in the STARTED state.
Troubleshooting: If an Object is Not in the STARTED State
If an object is not in the STARTED state, check for event messages in the Event 
Message System (EMS) log. Use the TSM EMS Event Viewer Application to view the 
EMS log:
1. From the File menu, select Log on.
2. Select the system.
3. Type the NonStop Kernel user name and password.
4. Click OK.
5. From the Setup menu, select either Timeframe, Source, or Subsystem criteria, or 
all three.
Refer to the Operator Messages Manual for cause, effect, and recovery information for 
event messages.
Example 3-36. SCF STATUS LINE Command
->STATUS LINE $LINE1
EXPAND Status LINE1
Name   State PPID  BPID  CIU-Path ConMgr-LDEV
$SATHO0  STARTED 2, 10 3, 7  A  91
Example 3-37. SCF STATUS PATH Command
->STATUS PATH $PATH
EXPAND Status PATH
Name   State  PPID BPID Lines #
$PSHOT  STARTED  2, 15 3, 15  2