Fibre Channel ServerNet Adapter Installation and Support Guide (G06.24+, H06.03+)

Installing an FCSA
Fibre Channel ServerNet Adapter Installation and Support Guide528254-010
2-21
DISK Configuration (Disk Drive Enclosure
Connection)
DISK Configuration (Disk Drive Enclosure
Connection)
For information about disk configuration for disk drive enclosures containing M8xxx
disks, see the SCF Reference Manual for the Storage Subsystem.
Verify the Disk Configuration
To check that the DISK object was successfully added to the configuration database,
issue the SCF STATUS ADAPTER adapter-name, DETAIL command.
is example shows WWNs of the SACs in the Port Name fields and it shows the LUNs
in the Configured Devices area of the display.
STORAGE - Detailed Status ADAPTER \IO.$ZZSTO.#FCSA.GRP-11.MOD-2.SLOT-1
Adapter Type..... FCSA
Flash Boot....... T0612G06 Flash Update Active.... Done
Flash Firmware... T0630G06 Flash Update Result.... Init
Location......... (11,2,1) Number of SACs......... 2
Part ID.......... 526217-001 POST Result............ PASSED
Power-1.......... ON Power-2................ ON
Revision Level... A01-01 Status................. PRESENT
Tracking Number.. MP0008 Vendor ID..............
ServerNet Addressable Controllers:
SAC \IO.$ZZSTO.#FCSA.SAC-1.GRP-11.MOD-2.SLOT-1:
SAC Number..... 1 Firmware.......... T0630G06
POST Result.... PASSED SAC SCSI ID.......
SAC Type....... FC Side.............. Both
Status......... PRESENT
Connection..... F port Node Name......... 20060B00001CE5F8
Port Id........ 65792 Port Name......... 50060B00001CE5F8
SAC State...... Ready SAC Subtype....... 1
Configured Devices ( group: 11, module: 2 ):
Slot Name State Substate Primary Backup
PID PID
1 $PT00-B STARTED 2,272 3,264
1 $PT01-B STARTED 3,283 2,273
1 $PT02-B STARTED 3,282 2,274
SAC \IO.$ZZSTO.#FCSA.SAC-2.GRP-11.MOD-2.SLOT-1:
SAC Number..... 2 Firmware.......... T0630G06
POST Result.... PASSED SAC SCSI ID.......
SAC Type....... FC Side.............. Both
Status......... PRESENT
Connection..... Loop Node Name......... 20060B00001CE5FA
Port Id........ 1 Port Name......... 50060B00001CE5FA
SAC State...... Ready SAC Subtype....... 1
Configured Devices ( group: 11, module: 2 ):
Slot Name State Substate Primary Backup
PID PID
1 $PT00-M *STARTED 2,272 3,264
1 $PT01-M *STARTED 3,283 2,273
1 $PT02-M *STARTED 3,282 2,274