Fibre Channel ServerNet Adapter Installation and Support Guide (G06.24+, H06.03+)

Replacing an FCSA
Fibre Channel ServerNet Adapter Installation and Support Guide528254-010
3-14
Obtain the Fibre Channel Port WWNs and Complete
the FCSA to ESS Configuration Form
Enter the STATUS ADAPTER, DETAIL command with the detail option for the FCSA:
3-> status $ZZSTO.#FCSA.GRP-11.MOD-3.SLOT-5, d
STORAGE - Detailed Status ADAPTER \MYSYS.$ZZSTO.#FCSA.GRP-11.MOD-3.SLOT-5
Adapter Type..... FCSA
Flash Boot....... T0612G06 Flash Update Active.... Done
Flash Firmware... ÿÿÿÿÿÿÿÿ Flash Update Result.... Init
Location......... (11,3,5) Number of SACs......... 2
Part ID.......... 526217 POST Result............ PASSED
Power-1.......... ON Power-2................ ON
Revision Level... A03-04 Status................. PRESENT
Tracking Number.. G2UKE8 Vendor ID..............
ServerNet Addressable Controllers:
SAC \MYSYS.$ZZSTO.#FCSA.SAC-1.GRP-11.MOD-3.SLOT-5:
SAC Number..... 1 Firmware.......... T0630G06
POST Result.... PASSED SAC SCSI ID.......
SAC Type....... FC Side.............. Both
Status......... PRESENT
Connection..... Loop Node Name......... 50060B00001D535D
Port Id........ 1 Port Name......... 50060B00001D535C
SAC State...... Ready SAC Subtype....... 1
Configured Devices ( group: 11, module: 3 ):
Slot Name State Substate Primary Backup
PID PID
5 $FISH107-P *STARTED 2,308 3,314
5 $FISH109-P *STARTED 2,306 3,316
5 $FISH106-B STARTED 1,332 0,328
5 $FISH110-P *STARTED 3,317 2,305
5 $FISH108-P *STARTED 3,315 2,307
5 $FISH103-B STARTED 2,310 3,312
5 $FISH111-P *STARTED 2,304 3,318
5 $FISH104-B STARTED 3,313 2,309
5 $FISH102-B STARTED 1,330 0,283
5 $FISH101-B STARTED 0,529 1,519
5 $FISH105-B STARTED 0,329 1,331
SAC \MYSYS.$ZZSTO.#FCSA.SAC-2.GRP-11.MOD-3.SLOT-5:
SAC Number..... 2 Firmware.......... T0630G06
POST Result.... PASSED SAC SCSI ID.......
SAC Type....... FC Side.............. Both
Status......... PRESENT
Connection..... Loop Node Name......... 50060B00001D535F
Port Id........ 1 Port Name......... 50060B00001D535E
SAC State...... Ready SAC Subtype....... 1
Configured Devices ( group: 11, module: 3 ):
Slot Name State Substate Primary Backup
PID PID
5 $FISH210-P *STARTED 1,344 0,332
5 $FISH204-B STARTED 1,336 0,324
5 $FISH209-P *STARTED 1,343 0,333
5 $FISH205-B STARTED 1,337 0,323
5 $FISH211-P *STARTED 1,345 0,331
5 $FISH206-B STARTED 1,338 0,322
5 $FISH203-B STARTED 1,335 0,325
5 $FISH207-P *STARTED 1,341 0,321
5 $FISH202-B STARTED 1,334 0,326
5 $FISH201-B STARTED 1,333 0,327
5 $FISH208-P *STARTED 1,342 0,320