Fibre Channel ServerNet Adapter Installation and Support Guide (G06.27+, H06.03+)
Installing an FCSA
Fibre Channel ServerNet Adapter Installation and Support Guide—528254-011
2-4
Start Completing the Configuration Forms
•
Define FCSAs in different modules in an IOAM enclosure or, better still, in different 
IOAM enclosures for the primary and backup DISK paths
ESS Connections
For connections to an ESS:
•
Define different FC switches for the primary and backup DISK paths
•
Define different ESSes for the primary and backup DISK images
For more information about fault-tolerance planning, see the Modular I/O Installation 
and Configuration Guide.
In order to complete the configuration form and perform the step DISK Configuration 
(ESS Connection) on page 2-15, you must obtain information from the ESS 
administrator. (Again, the choices about ports and LUNs provided by the ESS 
administrator should be determined by the overall, fault-tolerance strategy.)
For more information about fault-tolerance planning, see the Modular I/O Installation 
and Configuration Guide.
Disk Drive Enclosure Connections
Connections to M8xxx fibre channel disks in a disk drive enclosure require not only that 
FCSAs be defined through its group, module, and slot designations, but that disk drive 
enclosures be defined though shelf designations and that individual disks be defined 
through bay designations.
For purposes of fault-tolerance, you must choose bays on different shelves or in 
different chains of shelves when you locate primary and mirror disks. The system does 
not allow the of location primary and mirror disks on the same shelf or chain of shelves. 
For more information about fault-tolerance planning, see the Modular I/O Installation 
and Configuration Guide.
Start Completing the Configuration Forms 
ESS Connections
Print out the FCSA Configuration Form and the FCSA to ESS Connection Form from 
Appendix A, FCSA Configuration Forms for ESS Connections. If you are installing 
more than one FCSA, you will need to do a FCSA Configuration Form for each FCSA. 
You can use one FCSA to ESS Connection Form to record information about the 
WWNs of eight FCSAs. (Each FCSA requires two lines, one for each SAC.) You will 
not be able to complete the SAC 1 WWN and SAC 2 WWN information during this 
procedure; some of the fields must be obtained by using SCF to add a DISK after the 
FCSA is physically installed (see Obtain the Fibre Channel Port WWNs and Complete 
the FCSA to ESS Configuration Form on page 2-17).
1. Record the FCSA’s Part Number and Track ID on Your FCSA Configuration Form. 