Fibre Channel ServerNet Adapter Installation and Support Guide (G06.28+, H06.06+, J06.03+)

1. Press down and back on the latch. The latch slides under the top lip of the frame and secures
the adapter in place. The ejector latch clicks when the adapter is fully seated.
2. Disconnect the grounding clip of your ESD wrist strap from the rack or enclosure.
3. Connect the fibre channel cables to the fibre channel ports on the FCSA by lining up the
retaining clips with the ports and gently inserting them into the ports, one at a time.
CAUTION: Only handle the fibre channel cables in the plastic-protected area at the tip,
preferably at the clip itself. It is easy to break the glass inside the wire either by squeezing
the wire or by bending it too much.
Figure 2-3 Fibre Channel Cables
The green power-on LED at the bottom of the adapter should now be lit. If the LED is not
lit, either reseat the FCSA or install a different FCSA.
Label the Cables
1. Find the group, module, and slot of the IOAM enclosure in which the FCSA is installed.
2. Tag the fibre channel cables connected to the FCSA with physical labels, preferably at both
cable ends. The label should include:
A description of the equipment and connector to which the cables are to be connected
The slot location of the FCSA to which the cable is connected
The rack name, rack offset, and location text of the IOAM enclosure in which the FCSA
is installed
38 Installing an FCSA