Fibre Channel ServerNet Adapter Installation and Support Guide (G06.28+, H06.06+, J06.03+)

For more information about installing and configuring a M8201 Fibre Channel to SCSI router,
see the M8201R Fibre Channel to SCSI Router Installation Guide.
Verify the Tape Configuration
To check that the TAPE object was successfully added to the configuration database, issue the
SCF STATUS ADAPTER adapter-name, DETAIL command:
SAC \IO.$ZZSTO.#FCSA.SAC-1.GRP-15.MOD-2.SLOT-2:
SAC Number..... 1 Firmware.......... T0630G06
POST Result.... PASSED SAC SCSI ID.......
SAC Type....... FC Side.............. Both
Status......... PRESENT
Connection..... F port Node Name......... 50060B00001CE5F9
Port Id........ 262144 Port Name......... 50060B00001CE5F8
SAC State...... Ready SAC Subtype....... 1
Configured Devices ( group: 115, module: 2 ):
Slot Name State Substate Primary Backup
PID PID
2 $PT00-B STOPPED DOWN 3,271 2,267
2 $PT01-B STOPPED DOWN 3,272 2,266
SAC \IO.$ZZSTO.#FCSA.SAC-2.GRP-15.MOD-2.SLOT-2:
SAC Number..... 2 Firmware.......... T0630G06
POST Result.... PASSED SAC SCSI ID.......
SAC Type....... FC Side.............. Both
Status......... PRESENT
Connection..... Down Node Name......... 0000000000000000
Port Id........ 0 Port Name......... 210100E08B277DC3
SAC State...... Ready SAC Subtype....... 1
Configured Devices ( group: 115, module: 2 ):
Slot Name State Substate Primary Backup
PID PID
Verify the Tape Configuration 47