G06.25 Software Installation and Upgrade Guide
Updating Service Processor (SP) Firmware
G06.25 Software Installation and Upgrade Guide—529430-001
7-2
Alerts
Alerts
•
When using the TSM Service Application to update the service processor firmware, 
use the Firmware Update dialog box. Do not use the Single SP Firmware dialog 
box unless instructed to do so to recover from a failed service processor update.
•
Check that no other service processor firmware updates are in progress before 
updating service processor firmware.
•
Depending on your current RVU, you might have to reset all service processors in 
each ServerNet fabric (X and Y) before you begin updating service processor 
firmware. Failure to do so could result in the loss of certain critical system 
resources.
•
Update first the service processor firmware in the fabric (X or Y) containing the 
secondary master service processor (MSP). 
•
If the TSM service connection is lost, reconnect by using the TSM Service 
Application. If the OSM service connection is lost, reconnect using the OSM 
Service Connection.
•
If you have problems updating your SP firmware or resetting the SPs, see 
Recovery for Problems Updating SP Firmware (Using TSM) on page 7-15.
•
Yellow caution symbols might appear on enclosure icons, both in the physical view 
and in the tree pane, during the SP firmware update. These caution symbols 
should disappear after the system is loaded with the G06.25 RVU. 
•
As a precaution, download the SP firmware file (spntcde9), as described under 
Download the SP Firmware File to the System Console on page 7-6. If you have 
trouble updating your service processor and you cannot obtain a TSM service 
connection, you can use the spntcde9 file with the TSM Low-Level Link 
Application to update your SP, as described under Updating Firmware Using the 
TSM Low-Level Link Application on page 7-17. If OSM is installed, you can also 
download the SP firmware file (spntcde9) to the c:\osm\bin directory. You then 
use the OSM Low-Level Link. See Using OSM and Downloading the SP Firmware 
File to the System Console (Optional) on page 7-29.
•
Always check with Scout for the latest SP firmware SPRs.