G06.27 Software Installation and Upgrade Guide
Overview of Installing G06.27
G06.27 Software Installation and Upgrade Guide—540067-001
1-45
Visual Inspect (G06.20)
Visual Inspect (G06.20)
G06.20 includes the Inspect subsystem (T9226G06) and the Visual Inspect server
(T9756AAH) that support PIC programs and DLLs. This version of the server requires
version 2.4 of the Visual Inspect client (T7877AAD).
If you run client product version 2.3 with a G06.20 or later RVU, the client is connected
automatically to the previous version of the server (T9756AAG), and you will not be
able to debug or analyze snapshot dumps from a PIC process.
Unfortunately, client product version 2.4 is incompatible with earlier versions of the
server. Therefore, it can be difficult to debug from the same workstation on multiple
systems, where some systems run G06.20 or later RVUs and some run earlier RVUs.
There are two ways to approach this problem:
•
Install the latest server on the earlier NonStop systems, along with a compatible
version of the Inspect subsystem. You can install Visual Inspect server SPR
T9756AAH and Inspect subsystem SPR T9226AAK on an HP NonStop K-series
server running the D45.00 or later RVU, or on a NonStop S-series server running
G05.00 through G06.19 RVUs. See the T9756AAH softdoc.
•
Install both Visual Inspect client product versions 2.3 and 2.4 on the workstation.
However, you cannot run both at the same time, and version 2.3 can encounter
problems after 2.4 has run.
WAN Wizard Pro (G06.21 through G06.27)
The NonStop System Console Installer CD (S7X-SWV1/HNSC-SWV1, Update 6 and
Update 7) includes the WAN Wizard Pro client version 5.00. This client version is
compatible with G06.21 and later SUTs only. If you have to fall back to a pre-G06.21
RVU, you must de-install the previous WAN Wizard Pro and re-install the previous
WAN Wizard Pro on your system console. See the WAN Wizard Pro S04064 for
details.
X25AM
A new SCF line modifier, EMSFORFRMR, is provided so that an EMS message is
displayed when a link reset occurs from a Frame Reject (FRMR) condition on an
X25AM line. The modifier accepts values in the range from 0 to 200. Configure this
SCF modifier with a nonzero value to enable the generation of an EMS message
during an FRMR condition. (By default, the feature is disabled.)
See the X25AM Configuration and Management Manual and the X25AM Management
Programming Manual for more information.
Note. Note that the Visual Inspect client is an independent product and must be ordered
separately. HP strongly recommends that you upgrade both the client and server products
at the same time.
See all related softdocs for installation and configuration information.