G06.28 Software Installation and Upgrade Guide

Resuming Normal Operations
G06.28 Software Installation and Upgrade Guide541688-001
12-16
Upgrade the WAN Manager (T8365) (Optional)
Upgrade the WAN Manager (T8365) (Optional)
The version of WAN Manager (WANMGR) delivered in the G06.07 and later RVUs
removes the limitation of configuring 100 SWAN adapters. Starting with the G06.07
RVU, the number of adapters you can configure is determined by the amount of
memory available to the WAN manager. See the T8365 softdoc for information on the
default WANMGR startup configuration and how to use SCF to increase it.
Before updating the SWAN or SWAN 2 firmware (Appendix C, Updating SWAN
Concentrator CLIP Firmware), first configure the WAN Manager.
Upgrade the TNOS Server and TNOS Utility (Optional)
A miscoded TNS (nonnative) program can erroneously generate operand addresses
that are not adequately aligned for TNS instruction set architecture. The program can
then get unpredictable results when referencing those memory operands, on both TNS
and TNS/R systems, whether accelerated or not. The program might silently corrupt
adjacent data, compute wrong answers, or make wrong decisions.
Upgrade the TNOS Server and TNOS Utility to at least these versions:
T8666ACL or later (for TNOS Server)
T8667ACL or later (for TNOS Utility)
The marketing ID is SJ08V1, and the IP name is NonStop ODBC Server and Client.
See Support Note S02075B for details.
Configure Spooler Plus and Enform Plus
If you have these products, you need to modify them after you install the new RVU.