G06.28 Software Installation and Upgrade Guide

Overview of Installing G06.28
G06.28 Software Installation and Upgrade Guide541688-001
1-39
Safeguard
Safeguard
Starting with G06.25 RVU, you must not manually include Safeguard in the OSIMAGE.
Otherwise, a TACL prompt does not appear.
To configure the Safeguard software to run continuously from the time the system is
loaded until the time it is stopped, add the Safeguard software as a persistent process
to the Kernel subsystem. You must specify STARTUP=SYSTEM rather than KERNEL
when using the persistence manager with Safeguard. If you do not specify
STARTUP=SYSTEM and if your audit trails are not on $SYSTEM and no other
volumes are up, auditing is suspended. When the system is started, you must
intervene to resume auditing volumes. For detailed information on this and other
optional Safeguard installation procedures, see the T9750AER softdoc and the
Safeguard Administrator's Manual, Section 10.
There are considerations for possible fallback to a pre-G06.25 Safeguard T9750 SPR.
Compatibility with previous Safeguard SPRs is maintained. However, if the T9750AER
SPR is installed and the DISKFILE-PATTERN feature is used, you must evaluate if
equivalent nonpattern protection records are required after fallback. See the
T9750AER or later softdoc for details.
Starting in G06.26, if you have Safeguard volume-protection records added to prevent
or allow creation of OSS files, they are no longer required for OSS file creation. The
volume protection records can be revised or removed, depending on how they were
designed. If the volume protection records exist as part of a Guardian security policy
and have to be modified to accommodate OSS, the accommodations can now be
removed. For fallback information, see the Interactive Upgrade Guide 2.
S78000 G06.24 S78000 CRUs must be removed. These PMF
CRUs are supported for G06.16 and later
RVUs only. See the Interactive Upgrade Guide
2 for details.
S78000SE G06.25 S78000 CRUs must be removed. These PMF
CRUs are supported for G06.16 and later
RVUs only. See the Interactive Upgrade Guide
2 for details.
S88000 G06.24 S88000 CRUs must be removed. These PMF
CRUs are supported for G06.24 and later
RVUs only. See the Interactive Upgrade Guide
2 for details.
S88000SE G06.25 S88000SE CRUs must be removed. These
PMF CRUs are supported for G06.24 and
later RVUs only. See the Interactive Upgrade
Guide 2 for details.
Table 1-9. Upgrading to NonStop S-Series CRUs and Falling Back (page 2 of 2)
NonStop PMF CRU
Introduced in
this RVU Action