G06.28 Software Installation and Upgrade Guide

Overview of Installing G06.28
G06.28 Software Installation and Upgrade Guide541688-001
1-47
Visual Inspect
Visual Inspect
G06.20 and later RVUs include the Inspect subsystem (T9226G06 or later) and the
Visual Inspect server (T9756AAH or later) that support PIC programs and DLLs. This
product version of the server requires product version 2.4 of the Visual Inspect client
(T7877AAD).
If you run client product version 2.3 with a G06.20 or later RVU, the client is connected
automatically to the previous version of the server (T9756AAG), and you will not be
able to debug or analyze snapshot dumps from a PIC process.
Client product version 2.4 is incompatible with earlier versions of the server. Therefore,
it can be difficult to debug from the same workstation on multiple systems, where some
systems run G06.20 or later RVUs and some run earlier RVUs. There are two ways to
approach this problem:
Install the latest server on the earlier NonStop systems, along with a compatible
version of the Inspect subsystem. You can install Visual Inspect server SPR
T9756AAH and Inspect subsystem SPR T9226AAK on an HP NonStop K-series
server running the D45.00 or later RVU or on a NonStop S-series server running
G05.00 through G06.19 RVUs. See the T9756AAH softdoc.
Install both Visual Inspect client product versions 2.3 and 2.4 on the workstation.
However, you cannot run both at the same time, and version 2.3 can encounter
problems after 2.4 has run.
WAN Wizard Pro
The NonStop System Console Installer CD (S7X-SWV1/HNSC-SWV1, Update 7)
includes the WAN Wizard Pro client version 5.00. This client version is compatible with
G06.21 and later SUTs only. If you have to fall back to a pre-G06.21 RVU, you must
deinstall the previous WAN Wizard Pro and reinstall the previous WAN Wizard Pro on
your system console. See the WAN Wizard Pro Support Note S04064 for details.
X25AM
A new SCF line modifier, EMSFORFRMR, is provided so that an EMS message is
displayed when a link reset occurs from a Frame Reject (FRMR) condition on an
X25AM line. The modifier accepts values in the range from 0 to 200. Configure this
SCF modifier with a nonzero value to enable the generation of an EMS message
during an FRMR condition. (By default, the feature is disabled.)
For more information, see the X25AM Configuration and Management Manual and the
X25AM Management Programming Manual.
Note. Note that the Visual Inspect client is an independent product and must be ordered
separately. HP strongly recommends that you upgrade both the client and server products
at the same time.
See all related softdocs for installation and configuration information.