G06.29 Software Installation and Upgrade Guide
Preparing to Upgrade the Server Software
G06.29 Software Installation and Upgrade Guide—542744-003
4-16
Check the Status of the Spooler Collector
Check the Status of the Spooler Collector
Check that the spooler collector is active and not 100 percent full.
At a TACL prompt, start SPOOLCOM and issue a COLLECT, STATUS command. For 
example:
1> spoolcom $spls; collect, status
COLLECT STATE FLAGS CPU PRI UNIT DATA FILE %FULL
$S ACTIVE 3 , 1 154 4 $OPS0.SPL.DATA 44
Check the Tape Drive Status
Check that the tape drive to be used to install the SUT is started and online:
1. At a TACL prompt, enter:
> SCF STATUS TAPE $*
2. Verify that the STATUS TAPE display includes the tape subsystem you plan to use 
to load the SUT. For example:
STORAGE - Status TAPE \ELI.$SILO2
LDev State Primary Backup DeviceStatus
 PID PID
138 STARTED 0,295 1,279 ONLINE
3. If the tape subsystem you plan to use is not listed, select another tape drive or add 
the tape drive to your system configuration. The state of that tape drive must be 
STARTED, and the device status must be ONLINE.
4. If the status of the tape drive is stopped or not ready, start the tape drive and put 
the tape drive online.
Check Products With Possible Regressions
Check products that might experience regression during the upgrade. These products 
include Spooler Plus (T9593), Enform Plus (T0295), and CRE/RTL (T1269). If these 
products are present in your current configuration, take the recommended action after 
the upgrade is complete.
Spooler Plus (T9593)
Enter the following command to determine if Spooler Plus has been bound into the 
Spool object:
VPROC $SYSTEM.SYSTEM.SPOOL
If Spooler Plus has been bound into the Spool object, the VPROC output appears 
similar to:
Version Procedure: T9593D41^10MAY99^IPM^T9593AAD