G06.29 Software Installation and Upgrade Guide
Overview of Installing G06.29
G06.29 Software Installation and Upgrade Guide—542744-003
1-52
TNOS Server and TNOS Utility
Falling Back from TMF 3.3
If you add one or more auxiliary audit trails while TMF is started, you can fall back only
to G06.24 or a later RVU because the TMF audit reading facilities prior to the G06.24
RVU cannot handle auxiliary pointer (AUXPTR) records that specify a variable number
of audit trails. (Once configured, the number of audit trails generally remains constant).
TNOS Server and TNOS Utility
The TNOS Server (T8666) and the TNOS Utility (T8667), two components of HP
NonStop ODBC/MP, have been updated in G06.17 and later to correct data alignment
problems. To avoid data alignment problems, users of the TNOS Server and TNOS
Utility who are migrating to an RVU before G06.17 must also upgrade their TNOS
Server and TNOS Utility to these new versions:
•
T8666ACL or later (for TNOS Server)
•
T8667ACL or later (for TNOS Utility)
For post installation instructions, see the appropriate PVU softdoc. New EMS
templates are required for the T8666D35 PVU.
The marketing ID is SJ08V1, and the IP name is NonStop ODBC Server and Client.
For details concerning TNOS and data alignment problems, see Support Note
S02075B.
Visual Inspect
G06.20 and later RVUs include the Inspect subsystem (T9226G06 or later) and the
Visual Inspect server (T9756AAH or later) that support PIC programs and DLLs. These
product versions of the server require at least product version 2.4 of the Visual Inspect
client (T7877AAD or later).
If you run client product version 2.3 with a G06.20 or later RVU, the client is connected
automatically to the previous version of the server (T9756AAG), and you will not be
able to debug or analyze snapshot dumps from a PIC process.
Client product version 2.4 is incompatible with earlier versions of the server. Therefore,
it can be difficult to debug from the same workstation on multiple systems, where some
systems run G06.20 or later RVUs and some run earlier RVUs. There are two ways to
approach this problem:
•
Install the latest server on the earlier NonStop systems, along with a compatible
version of the Inspect subsystem. You can install Visual Inspect server SPR
T9756AAH and Inspect subsystem SPR T9226AAK on an HP NonStop K-series
server running the D45.00 or later RVU or on a NonStop S-series server running
G05.00 through G06.19 RVUs. See the T9756AAH softdoc.