G06.30 Software Installation and Upgrade Guide
G06.30 Software Installation and Upgrade Guide—543764-002
14-1
14
Backing Out the DSM/SCM Revision
This section describes how to submit a DSM/SCM backout request to return to your
previous RVU from G06.30.
You must run the DSM/SCM FALLBACK macro from the ZDSMSCM subvolume. The
FALLBACK macro can be exported from any D46 PVU in the DSM/SCM archive and
then placed in the ZDSMSCM subvolume. You must run the FALLBACK macro if you
are not already running DSM/SCM T6031D46^ABK or later.
Before Backing Out the Revision
1. Confirm that the spooler is active and not 100 percent full.
a. At a TACL prompt, start SPOOLCOM and issue a COLLECT, STATUS
command. For example:
12> spoolcom $spls; collect, status
COLLECT STATE FLAGS CPU PRI UNIT DATA FILE %FULL
$S ACTIVE 3 , 1 154 4 $OPS0.SPL.DATA 4
b. If the spooler is not active, start the spooler.
You will use the spooler to print out operator instructions when backing out the
revision.
2. Start the TMF subsystem and DSM/SCM if they are not already running. For
example:
4> TMFCOM START TMF
5> volume $
dsmscm_vol.ZDSMSCM
6> RUN STARTSCM
where $dsmscm_vol is the DSM/SCM volume.