G06.32 Software Installation and Upgrade Guide

Preparing to Upgrade the Server Software
G06.32 Software Installation and Upgrade Guide546068-002
5-13
Check the Status of the SACs
112 $ZTCP0 0,288 1,278 (48,0 ) 32000 200 \ELI.$SYSTEM.SYS00.TCPIP
113 $ZTNT0 0,298 1,276 (46,0 ) 6144 170 \ELI.$SYSTEM.SYS00.TELSERV
140 $ZTN20 2,287 3,273 (46,0 ) 6144 170 \ELI.$SYSTEM.SYS00.TELSERV
142 $ZTC20 2,286 3,272 (48,0 ) 32000 200 \ELI.$SYSTEM.SYS00.TCPIP
196 $ZPHI 0,268 1,288 ( 1,0 ) 4024 198 \ELI.$SYSTEM.SYS00.EMSACOLL
199 $Z14W 3,35 ( 1,30) 132 150 \ELI.$SYSTEM.SYS00.EMSDIST
205 $Z14X 2,23 ( 1,30) 132 150 \ELI.$SYSTEM.SYS00.EMSDIST
Check the Status of the SACs
Check the status of the ServerNet Addressable Controllers (SACs) in the ServerNet
LAN Systems Access (SLSA) subsystem using SCF. The SACs must be in the
STARTED state before continuing with the migration:
5> scf
SCF - T9082G02 - (15APR98) (04MAR98) - 02/23/99 14:11:31 System \ELI
Copyright Tandem Computers Incorporated 1986 - 1998
(Invoking \ELI.$SYSTEM.SUPER.SCFCSTM)
1-> assume $zzlan
$ZZLAN 2-> status sac *
SLSA Status SAC
Name Owner State Trace Status
$ZZLAN.MIOE0.0 0 STARTED OFF
$ZZLAN.E0153.0 0 STARTED OFF
$ZZLAN.E0153.1 0 STARTED OFF
$ZZLAN.TR1.0 0 STARTED OFF
Check Disk Subsystem Status
Verify that these disk volumes are started:
$SYSTEM (mirrored volume)
The volume containing the DSM/SCM target subvolume (by default $DSMSCM)
The DSM/SCM Archive volume (by default $AUDIT)
1. At a TACL prompt, enter:
> SCF STATUS DISK $*, SUB magnetic
2. Verify that the STATUS DISK display includes all the disk subsystems shown in this
example:
3> scf status disk $*, sub magnetic
SCF - T9082G02 - (15APR98) (04MAR98) - 02/23/99 14:23:59 System \ELI
Copyright Tandem Computers Incorporated 1986 - 1998
STORAGE - Status DISK \ELI.$SYSTEM
LDev Primary Backup Mirror MirrorBackup Primary Backup
PID PID
6 *STARTED STARTED *STARTED STARTED 0,257 1,257
STORAGE - Status DISK \ELI.$DSMSCM
Note. See the
DSM/SCM Users
Guide for information on these DSM/SCM database volumes.