GDSX Manual

Operations and Support
Extended General Device Support (GDSX) Manual134303
3-26
Fault Messages
Fault Messages
These warning and error messages are handled by EMS. They appear at the EMS
terminal along with the EMS event messages.
A fault message may be generated by TSCODE or by a USCODE call to the FAULT
procedure. (See the procedure description in Section 8.) Table lists the number ranges
for fault messages.
All fault messages have the following format:
hh is hour
mi is minute
ss is second
mm is month
dd is day
yy is year
name is process name
Fault messages generated by converted GDSX processes always show the PIN with a
value of 255.
Here is an example of a fault message:
09:23:00 04/10/91 $GDSX (06,37) error - TERM 01
($GDSX.#T27B)
Fault # 104 P =
%00.047502
Table 3-7 contains a summary of the fault messages issued by TSCODE. Fault numbers
0-4 and 10-13 are usually generated by the GDSX trap handler.
Table 3-6. Number Ranges for Fault Messagesw
Number
Range Type of Messages
0-100 Reserved for faults detected by TSCODE
101-200 Warning type of faults detected by a DEVICE^HANDLER task
201-300 Error type of faults detected by a DEVICE^HANDLER task
301-400 Warning type of faults detected by a LINE^HANDLER task
401-500 Error type of faults detected by a LINE^HANDLER task
hh:mi:ss: mm/dd/yy name (cpu,pin) message-type - text