Gigabit Ethernet 4-Port Adapter Installation and Support Guide
Replacing a G4SA
Gigabit Ethernet 4-Port ServerNet Adapter Installation and Support Guide—528166-006
3-9
Stop the Communications Lines and SWAN
Concentrator Line Using the G4SA
3. Use the SCF STOP DEVICE command to stop the WAN subsystem IOPs.
STOP DEVICE $ZZWAN.#device-name
4. Use the SCF STATUS DEVICE command to verify that the WAN subsystem IOPs
are in the STOPPED state (see Example 3-15).
STATUS DEVICE $ZZWAN.#device-name
5. Use the SCF STOP ADAPTER command with the SUB ALL option to stop the
SWAN concentrator.
STOP ADAPTER $ZZWAN.#adapter-name, SUB ALL
The SUB ALL option stops the ADAPTER object and its subordinate objects.
6. Use the SCF STATUS ADAPTER command to verify that the SWAN concentrator
is in the STOPPED state (see Example 3-16).
STATUS ADAPTER $ZZWAN.#adapter-name
Example 3-14. SCF STATUS PATH Command
->STATUS PATH $PATH
EXPAND Status PATH
Name State PPID BPID Lines #
$PATH STOPPED 2, 15 3, 15 2
Example 3-15. SCF STATUS DEVICE Command
->STATUS DEVICE $ZZWAN.#LINE1
WAN Manager STATUS DEVICE for DEVICE \COWBOY.$ZZWAN.#LINE1
State :........ STOPPED
LDEV number.... 110
PPIN........... 2 ,13 BPIN......... 3 ,14
Example 3-16. SCF STATUS ADAPTER Command
->STATUS ADAPTER $ZZWAN.#S01
WAN Manager STATUS ADAPTER for ADAPTER \COWB0Y.$ZZWAN.#S01
State....... STOPPED
Number of clips. 3
Clip 1 status : CONFIGURED
Clip 2 status : CONFIGURED
Clip 3 status : CONFIGURED