Gigabit Ethernet ServerNet Adapter Installation and Support Guide

Introduction to the Gigabit Ethernet ServerNet
Adapter (GESA)
Gigabit Ethernet Adapter Installation and Support Guide523628.005
1-5
GESA-F External Connectors, Indicators, and
Cables
The GESA-C cable specifications and cable distances are:
GESA-F External Connectors, Indicators, and Cables
The GESA-F external connectors consist of one 1000 Base-SX SC duplex connector.
The GESA-C external indicators consist of:
Two status LEDs for the GESA-F
Two status LEDs for the Gigabit Ethernet port
Figure 1-2 on page 1-6 shows the position of these external connectors and indicators.
The two GESA-F status LEDs are controlled by the Service Processor (SP) and
indicate the state of the adapter:
The Gigabit Ethernet port status LEDs indicate the activity on and state of the Gigabit
Ethernet port:
Port Type Connector Cable Media Maximum Distance
10 Base-T (802.3) RJ-45 Category (CAT) 3,
4, or 5 unshielded
twisted-pair (UTP)
cable
100 Meters (328 feet)
100 Base-TX (802.3u) RJ-45 CAT 5 UTP (2-pair) 100 Meters (328 feet)
1000 Base-T (802.3ab) RJ-45 CAT 5 UTP (4-pair) 100 Meters (328 feet)
These are customer-supplied cables.
LED GESA State
Green Power-on
Amber Fault condition
LED State Description
1000 On
Off
Gigabit Ethernet link is connected
Gigabit Ethernet link is not connected
ACT Blinking
On
Off
Burst of data detected on the port
Data is streaming on the port
No data is detected on the port