Replacing a GESA
Gigabit Ethernet Adapter Installation and Support Guide523628.005
3-6
Identify Any Communications Lines and ServerNet
Wide Area Network (SWAN) Using the GESA
4. Use the SCF INFO LINE command for the PAM line you identified in Step 3 to
determine the PAM Line associated with the LIF on the GESA to be replaced (see
Example 3-5
). Write down the associated LIF and PAM line on your worksheet.
INFO LINE $line-name
5. Use the SCF NAMES SUBSYS command to identify the IPXPROTO processes
configured on the system (see Example 3-6).
NAMES SUBSYS $ZMGR
Example 3-4. SCF NAMES Command
->NAMES $ZZPAM
PAM Names \SAMCAT.$ZZPAM
PROCESS
$TOK1 $ZZPAM
LINE
$TOK1
PORT
$TOK1.#L1P0002 $TOK1.#L1P0004
MSAP
$TOK1.#SNATR
Example 3-5. SCF INFO LINE Command
->INFO LINE $TOK1
PAM Info LINE
Name MAXREQUESTSIZE LIF NAME LIF TYPE LIF MAC ADDRESS
$TOK1 3200 L018 ENET 08:00:8E:00:D1:96
Example 3-6. SCF NAMES SUBSYS Command
->NAMES SUBSYS $ZMGR
IPXSPX Names SUBSYS \HIMA.$ZMGR
SUBSYS
$ZMGR
PROCESS
$ZNV0
SERVER
$ZNV0.#SAP
PROCESS
$ZNV1
SERVER
$ZNV1.#SAP