Gigabit Ethernet ServerNet Adapter Installation and Support Guide

Gigabit Ethernet Adapter Installation and Support Guide523628.005
B-1
B
Preparing a GESA for PMF or IOMF
CRU Replacement
A GESA depends on X-fabric or Y-fabric communication from the PMF or IOMF CRUs
in the group of enclosures where the GESA is installed.
For NonStop S-series servers, replacing a PMF or IOMF CRU can result in loss of
access to the GESA unless fault tolerance is ensured.
1. Before replacing a PMF or IOMF CRU, use the SLSA SCF STATUS SAC
command with the DETAIL option to verify the associated GESAs fault tolerance:
a. Verify that the Current Access list indicates access to more than one
processor as shown in the following example.
b. Verify that both the X and Y fabrics are UP as shown in the following example.
-> STATUS SAC $ZZLAN.G0153.0 , DETAIL
SLSA Detailed Status SAC \ABBY.$ZZLAN.G0153.0
Current Access........... ( 1, 2, 3 )
Last Download Time....... 27 JAN 2000, 7:11:49:662
Last Error............... (0, 0, 0)
Owner CPU................ 1
State.................... STARTED
Trace Filename...........
Trace Status............. OFF
Fabric Status
CPU Accesslist Fabric-X Fabric-Y
-------------- -------- --------
1 UP-PRIMARY UP
2 UP-PRIMARY UP
3 UP-PRIMARY UP