Guardian Performance Analyzer (GPA) User Guide
Guardian Performance Analyzer (GPA) User Guide – (544541-006) Page 41 of 131 
7> PARAM classname section-type 
classname specifies the process class the optional report is run for. The classnames 
are: 
  SYSTEM 
SUBSYSTEM 
PATHWAY 
SERVER 
TRANSIENT 
OTHER 
You can select more than one section for the optional report by setting one PARAM for 
each class. 
Section-type specifies the type of output GPA should produce. The options are: 
  SUMMARY 
DETAIL 
An optional section is run for each of the PARAMs declared. Setting a PARAM to any 
other type than SUMMARY or DETAIL results in the section for that classname 
not being produced. When you select DETAIL, the summary section is included. 
For example, to run a detail section for the SYSTEM class and a summary for each 
of the others, set the following six PARAMS:  
  8> PARAM SYSTEM DETAIL 
9> PARAM SUBSYSTEM SUMMARY 
10> PARAM PATHWAY SUMMARY 
11> PARAM SERVER SUMMARY 
12> PARAM TRANSIENT SUMMARY 
13> PARAM OTHER SUMMARY 
The default section-type is DETAIL. To refrain from printing the optional report, 
specify: 
  14> PARAM classname NOPRINT 
To suppress printing of the textual report only, enter: 
  15> PARAM TEXT NOPRINT 
3. Run GPA to perform the analysis. Set the volume and subvolume to the location of 
your measurement data and enter: 
  16> RUN $SYSTEM.ZGPA.OBEYTUNE 
This assumes GPA has been installed to $SYSTEM.ZGPA. If this is not the case, 
substitute the correct $volume.subvolume in the above command line. GPA 
processes the data collected by Measure and generates the reports as well as the 