Guardian Procedure Calls Reference Manual (G06.25+)

Guardian Procedure Calls (S)
Guardian Procedure Calls Reference Manual522629-013
14-81
SETMODE Procedure
37,
continued
Primary status bits are:
[0].<0:8> = 0 undefined
.<9> = 1 reserved
.<10:12> = 0 no faults
= 1 printer idle
= 2 paper out
= 3 end of ribbon
= 4 data parity error
= 5 buffer overflow
= 6 cover open
= 7 auxiliary status available
.<13> = 0 buffer not full
= 1 buffer full
.<14> = 0 OK
= 1 device power on error
.<15> = 0 OK
= 1 device not ready
If primary status
last-params[0].<10:12> = 7, auxiliary status word is:
[1].<0:7> = undefined
.<8:11> = fault display status (most significant hex digit)
.<12:15> = fault display status (least significant hex digit)
Fault display status summary:
Operator Aux Status Aux Status Problem
Display .<8:11> .<12:15> Description
None 0 0 No faults
E01 0 1 Paper out
E03 0 3 Cover open
E06 0 6 End of ribbon
E0707Break
E11 1 1 Parity error
E12 1 2 Unprintable character
E22 2 2 Carrier loss
E23 2 3 Buffer overflow
E30 3 0 Printwheel motor fault
E31 3 1 Carriage fault
E32 3 2 Software fault
E34 3 4 Hardware fault
Table 14-4. SETMODE Functions (page 14 of 34)
function Parameters and Effect