Guardian Procedure Errors and Messages Manual

Cause A file-system error occurred.
Effect The requested operation is not completed.
Recovery Corrective action depends on the error. Check Table 25 for an explanation of the status-1
and status-2 parameters.
Table 25 Supplementary Status Values
Explanationstatus-2status-1Error
File-system error x received during an
open of the nonresident template file.
x2-13
File-system error x received during a read
of the nonresident template file.
x1-13
ALLOCATESEGMENT error x received
during allocation of the private segment
x7-14
Nonresident template file error x, in
which x has the following values: -1 File
code is not 844.
x-2-15
-2 F ile is not a disk file.
-3 File is not key-sequenced.
-4 File has wrong record size.
-5 File has wrong primary key definition.
-14 ZSPI-ERR-ZGRD-ERR Guardian procedure error
Cause An error occurred during allocation of the private segment; this error is returned from
ALLOCATESEGMENT or MOVEX.
Effect The requested operation is not completed.
Recovery Corrective action depends on the error. Check Table 25 (page 217) for an explanation
of the status-1 and status-2 parameters.
-15 ZSPI-ERR-INF-FILE Invalid template file
Cause The template file is invalid.
Effect The requested operation is not completed.
Recovery Corrective action depends on the error. Check Table 25 (page 217) for an explanation
of the status-1 and status-2 parameters.
-16 ZSPI-ERR-CONTINUE More text is available
Cause The entire representation does not fit in the number of lines specified by the printlines
parameter.
Effect The amount of text is limited by the printlines parameter setting.
Recovery Call again to get the next portion.
-26 ZSPI-ERR-NO-SCANID See service provider.
Cause No free scan ID was available. Currently, no more than two scan IDs can be active
simultaneously.
Effect The requested operation is not completed.
Error Codes 217