Guardian Programming Reference Summary for pTAL and TAL
SETMODE Operations
Guardian Programming Reference Summary for pTAL and TAL—522631-001
11-13
37 
(continued)
Primary status bits are:
[0].<0:8> = 0  undefined
.<9> = 1  reserved
.<10:12>
= 0 no faults
= 1  printer idle
= 2 paper out
= 3  end of ribbon
= 4  data parity error
= 5  buffer overflow
= 6  cover open
= 7 auxiliary status available
.<13> = 0  buffer not full
    = 1 buffer full
.<14> = 0  OK
    = 1  device power on error
.<15> = 0  OK
    = 1  device not ready
If primary status last-params [0].<10:12> = 7, auxiliary status word is:
[1].<0:7>= undefined
.<8:11>= fault display status (most significant hex digit)
.<12:15>= fault display status (least significant hex digit)
Fault display status summary:
Operator Aux Status Aux StatusProblem
Display. <8:11>.<12:15>Description
None 00 No faults
E01 01 Paper out
E03 03  Cover open
E06 06  End of ribbon
E07 07 Break
E11 11  Parity error
E12 12  Unprintable character
E22 22  Carrier loss
E23 23 Buffer overflow
E30 30  Printwheel motor fault
E31 31 Carriage fault
E32 32 Software fault
E34 34  Hardware fault
<function> Parameters and Effect