Guardian User's Guide
Monitoring Hardware Components
Guardian User’s Guide—425266-001
19-10
Checking Disk Status
•
To display the summary status of the mirror disk of the volume $DATA00, enter:
-> STATUS $DATA02-M
•
To display the status of all disks, enter:
-> STATUS DISK $*
•
To display the detailed status of the disk $DATA01, enter:
-> STATUS $DATA01, DETAIL
47-> STATUS DISK $DATA02-M
STORAGE - Status DISK \SHARK.$DATA02-M
LDev  Path   PathStatus State  SubState  Primary  Backup
              PID  PID
 62 MIRROR INACTIVE  STOPPED HARDDOWN  0,268 1,265
29-> STATUS DISK $*
STORAGE - Status DISK \SHARK.$DATA02
LDev  Primary  Backup  Mirror  MirrorBackup  Primary  Backup
            PID   PID
 62  STOPPED  STOPPED  STOPPED  STOPPED  0,268  1,265
STORAGE - Status DISK \SHARK.$DATA03
LDev  Primary  Backup  Mirror  MirrorBackup  Primary  Backup
            PID   PID
 61  STOPPED  STOPPED  STOPPED  STOPPED  0,269  1,264
…
35-> STATUS $DATA01, DETAIL
STORAGE - Detailed Status DISK \SHARK.$DATA01
Disk Path Information:
 LDev Path  PathStatus State SubState Primary Backup
                            PID   PID
 63  PRIMARY  ACTIVE  STARTED   0,267  1,266
 63  BACKUP  INACTIVE  STARTED    0,267  1,266
 63 MIRROR  ACTIVE  STARTED   0,267 1,266
 63 MIRROR-BACKUP INACTIVE  STARTED         0,267 1,266
General Disk Information:
 Device Type........... 3    Device Subtype........... 40
 Primary Drive Type.... 4565-1  Mirror Drive Type........ 4565-1
 Physical Record Size.. 4096   Priority................. 220
 Library File..........
 Program File.......... \SHARK.$SYSTEM.SYS00.TSYSDP2
 Protection............ MIRRORED
Usage Information:
 Capacity (MB)......... 2000.09 Free Space (MB).......... 290.76 (14.53%)
 Free Extents.......... 16   Largest Free Extent (MB). 172.42
Hardware Information:
 Path   Location     Power   Physical Status
    (group,module,slot)
 PRIMARY   (1,1,3)     DUAL   PRESENT
 MIRROR   (1,1,4)     DUAL   PRESENT