Guardian User's Guide
Monitoring Hardware Components
Guardian User’s Guide—425266-001
19-21
Checking NonStop™ TM/MP Status
The data shown in the report means:
Check the meaning of the code in Determining Device States
 on page 19-5 if the State is 
other than STARTED. Depending upon the type of problem, follow your established 
procedures for problem reporting and escalation. 
For more information about line handlers, see the Expand Configuration and 
Management Manual. 
Example
To check the detailed status of line $LHCS6S, enter:
-> SCF STATUS LINE $LHCS6S, DETAIL
A listing such as this is sent to your home terminal: 
Checking NonStop™ TM/MP Status
This subsection explains how to check the status of the NonStop™ Transaction 
Manager/MP (TM/MP) and the data volumes it protects. 
The main component of NonStop™ TM/MP is the Transaction Management Facility 
(TMF) subsystem, a standard Compaq tool that maintains the consistency, integrity, and 
durability of a distributed database that is being updated by concurrent transactions. You 
use the TMFCOM command interface or the TM View graphical user interface to 
manage and operate the TMF subsystem, and as a system operator, you might check 
TMF status in your routine system monitoring.
To monitor the basic components of the TMF subsystem using TMFCOM, enter:
> TMFCOM
~ STATUS TMF
Name Specifies the name of the PATH object
State Indicates the summary state of the path. The path is in either the 
STARTED, STARTING, DIAGNOSING (for T/3880 concentrators 
only) or STOPPED state.
PPID Specifies the primary process ID
BPID Specifies the backup process ID
ConMgr-LDEV Contains the LDEV of the Concentrator Manager. This field applies 
only to T/3880 concentrator lines
- > STATUS LINE $LHCS6S, DETAIL
PPID.................... ( 3, 24) BPID................ ( 2, 24)
State................... STOPPED Path LDEV...........    50 
Trace Status............   OFF Clip Status......... UNLOADED 
ConMgr-LDEV.............   49 
Path-prim 
Path-alter