Error Messages for NonStop™ IPX/SPX
IPX/SPX Configuration and Management Manual—425731-001
D-10
IPXSPX 00018
Cause. The ADD command failed for one of the following reasons.
•
The SLSA logical interface (LIF) is down, or the LIF is not accessible.
•
The specified processors are not on the access list.
•
The specified IOPORTNAME is incorrect.
Effect. The command is not executed, so the IPXPROTO process is not defined to the
NonStop™ IPX/SPX subsystem.
Recovery. Verify that the specified IOPORTNAME exists, is configured for QIO, and
is in the correct format. Refer to the Guardian Procedure Calls Reference Manual for
additional information about any procedure names, such as PROCESS_CREATE_, that
appear in the message.
IPXSPX 00018
Cause. A particular attribute has been entered more than once.
Effect. The command is not executed.
Recovery. Retry the command after removing duplicate attributes.
IPXSPX 00019
Cause. A required attribute has not been entered by the user.
Effect. The command is not executed.
Recovery. Retry the command using the correct attribute set.
IPXSPX 00020
Cause. This is an internal error that occurred while parsing an SCF command: an
invalid case value was generated with no associated case label.
Effect. The command has no effect.
Recovery. This could be a serious problem. Contact your service provider.
IPXSPX 00018 Duplicate attribute.
IPXSPX 00019 Required attribute is missing.
IPXSPX 00020 IPX SCF Product Module Internal Error: Case
value out of range.