L700 (CTL700) Installation and User's Guide (G06.24+, H06.03+)
Installing the Tape Library
L700 (CTL700) Installation and User’s Guide—527338-004
3-9
Fiber Cables
SCSI Drive Connections
For SCSI operations, check that the length restrictions are consistent with for 
the channel type being used.
Be sure to label each tape drive with its server or client address and to label the 
cables. These labels provide reliable identification for any future maintenance on 
the tape drives. 
Direct Connection
For installations requiring SCSI direct data path configurations for each tape 
drive:
1. Open the left rear door.
2. Connect the client data cable for the first tape drive to the appropriate 
connector at the rear tape library frame.
Fiber Cables
Proper Fibre Channel components must be used. The components consist of a 
CT9800FC Fibre Channel converter, a short wave multimode GBIC, and multimode 
fiber cables. A GBIC connector must be used. The GBIC is mounted in the CT9800FC 
Fibre Channel converter, and it must be a black multimode GBIC.
For more information refer to Appendix A, Connecting the Fibre Channel Components 
for the CTL700 Tape Library.
For part numbers and descriptions for the fiber cables using the short wave GBICs, 
refer to Appendix B, Multimode Fiber-Optic Cables. 
Caution. Do not connect SCSI cables to the tape drives until they are configured for 
operation.