LAN Configuration and Management Manual
SCF Commands for the SLSA Subsystem
LAN Configuration and Management Manual—520469-012
4-116
STATUS PIF Command
STATUS PIF DETAIL for a FESA
The format of the display for the STATUS PIF command with the DETAIL option for the
PIF on a FESA adapter is:
CPUs with Data Path
lists processors that have a successful data path for the specified PIF. NONE
indicates that no processor has a data path through the PIF. The processors are
listed in numerical order.
Last Error
indicates the severity, origin, and error code of the last error encountered by the
PIF. (0,0,0) indicates no errors have occurred.
State
indicates the current state of the PIF.
Trace Filename
indicates the name of the file that stores current trace information if TRACE is ON
for the specified PIF.
Trace Status
indicates whether TRACE is active on the specified PIF.
Duplex
indicates whether the line is full or half duplex. Full duplex means that data can be
sent and received at the same time. Half duplex means that data can be sent in
only one direction at a time. Invalid means the adapter is not properly connected to
the hub.
Line Speed
indicates the line speed. Possible values are 100 Mbit/sec, 10 Mbit/sec or Invalid.
Invalid means the adapter is not properly connected to the hub.
-> STATUS PIF F0152.0.A , DETAIL
CPUs with Data Path..... ( 0, 1 )
Last Error.............. (3, LANMON, 2038)
State................... STARTED
Trace Filename..........
Trace Status............. OFF
FESA Controller Status
Duplex...................... HALF
Line Speed.................. 100 Mbit/sec
Link Pulse State............ Up