LAN Configuration and Management Manual
SCF Commands for the SLSA Subsystem
LAN Configuration and Management Manual—520469-012
4-118
STATUS PIF Command
Line Speed
indicates the line speed. Values are 1000 Mbit/sec, 100 Mbit/sec, 10 Mbit/sec or
Invalid. Invalid means that the adapter is not connected properly to the hub.
For GESA, LINESPEED defaults to 1000 Mbit/s when the Interface Type is
Fiber (SX) or Fiber (LX), even if you specified a LINESPEED of 10 or 100 Mbit/s.
(Use the STATUS PIF command to check the actual LineSpeed of the
communication line. Use the INFO PIF display to check the user-configured
LineSpeed Value.)
Link Pulse State
indicates the current state of the link pulse on the physical Ethernet link. This field
is only applicable to the E4SA, FESA, GESA, and G4SA. The value of this field
can be UP (normal condition) or DOWN.
STATUS PIF DETAIL for a G4SA
The format of the display for the STATUS PIF command with the DETAIL option for the
PIF on an G4SA adapter is:
CPUs with Data Path
lists processors that have a successful data path for the specified PIF. NONE
indicates that no processor has a data path through the PIF. The processors are
listed in numerical order.
Last Error
indicates the severity, origin, and error code of the last error encountered by the
PIF. (0,0,0) indicates that no errors have occurred.
State
indicates the current state of the PIF.
SLSA Detailed Status PIF \SYS.$ZZLAN.G11123.0.A
CPUs with Data Path...... ( 0, 1, 2, 3, 4, 5, 6, 7 )
Interface Status......... OFF
Last Error............... (0, 0, 0)
State.................... STARTED
Trace Filename...........
Trace Status............. OFF
G4SA Adapter Status
Duplex................... FULL
Line Speed............... 100 Mbit/sec
Link Pulse State......... UP
Line Type ........... Copper
JumboFrame............... OFF
Filter Count............. 27