LAN Configuration and Management Manual
SCF Commands for the SLSA Subsystem
LAN Configuration and Management Manual—520469-012
4-119
STATUS PIF Command
Trace Filename
indicates the name of the file that stores current trace information if TRACE is ON
for the specified PIF.
Trace Status
indicates whether TRACE is active on the specified PIF.
Duplex
indicates whether the line is full-duplex, half-duplex, or invalid. Full-duplex means
that data can be sent and received at the same time. Half-duplex means that data
can be sent in only one direction at a time. Invalid means that the adapter is not
connected properly to the hub.
Line Speed
indicates the line speed. Values are 1000 Mbit/sec, 100 Mbit/sec, 10 Mbit/sec or
Invalid. Invalid means that the adapter is not connected properly to the hub.
For G4SA, LINESPEED defaults to 1000 Mbit/s when the line type is fiber, even if
you specified a LINESPEED of 10 or 100 Megabits/second (Mbit/s). (Use the
STATUS PIF command to check the actual LINESPEED of the communication line.
Use the INFO PIF display to check the user-configured LINESPEED value.)
Line Type
indicates the line type, which is either copper or fiber. This field is only displayed
for the G4SA adapter type.
Link Pulse State
indicates the current state of the link pulse on the physical Ethernet link. This field
is only applicable to the E4SA, FESA, GESA, and G4SA adapter types. The value
of this field can be UP (normal condition) or DOWN.
JumboFrame
indicates the current state of the link pulse on the physical Ethernet link. This field
is only displayed for the G4SA adapter type. The value of this field can be UP
(normal condition) or DOWN.
For G4SA, the actual setting of the JumboFrame attribute will be displayed, and
jumbo frames cannot be used for line speeds less than 1 Gigabits/second (Gbit/s)
even if the JumboFrame attribute has been set to ON. If the INFO PIF, detail
command shows JumboFrame ON and the STATUS PIF, detail command shows
JumboFrame OFF, the G4SA adapter cannot handle jumbo frames.
Filter Count
indicates how many filters are registered with the PIF. This field is only displayed
for the G4SA adapter type.