LAN Configuration and Management Manual
SCF Commands for the SLSA Subsystem
LAN Configuration and Management Manual—520469-012
4-136
TRACE MON Command
Bulk I/O tracing is faster and should eliminate most data loss. The default is 
BULKIO. BULKIO cannot be used with NOCOLL.
COUNT count
specifies the number of trace records to be captured. count is an integer in the 
range -1 through 32767. If count is omitted or if count equals -1, records are 
accumulated until the trace is stopped.
LOCKSIZE locksize
designates how much memory space, in units of pages, is locked down at one 
time. LOCKSIZE can be specified only when a trace is initiated. locksize is an 
integer in the range 4 through 1024. locksize must be less than or equal to pages. 
If PAGES is not specified, locksize must be less than or equal to 64. If LOCKSIZE 
is omitted, locksize is the lesser of pages and 64.
NOCOLL
specifies that trace data from the extended segment is written to the disk file 
specified in TO file-spec only when one of the following occurs:
The trace is stopped.
The number of trace records written to the extended data segment equals the 
count specified in the TRACE command that started the trace. When the trace 
facility detects this condition, the trace records from the extended data 
segment are written to the disk file and the trace is stopped automatically. You 
don’t need to issue a separate TRACE command to stop the trace. If NOCOLL 
is not specified, a trace collector process reads the trace records from the 
extended data segment and writes them to the disk file as they become 
available.
The NOCOLL option cannot be used with the BULKIO option.
PAGES pages
designates how much space, in units of pages, is allocated in the extended data 
segment used for tracing. PAGES can be specified only when a trace is being 
initiated. pages is an integer in the range 4 through 1024 or is equal to 0. If PAGES 
is omitted or pages equals 0, the default value of 64 pages is assumed.
RECSIZE size
specifies the length of the data in the trace-data records. You can specify size as 0 
or as an integer in the range 16 through 4050. The length of the trace header, 
which is eight bytes, is not included in size. If RECSIZE is omitted or if size equals 
0, a default value of 120 bytes is assumed.