SCF Error Messages
LAN Configuration and Management Manual520469-012
B-13
SLSA 00064
Cause. The attribute in question conflicted with one or more of the other attributes on
the command line.
Effect. SCF ignores the command.
Recovery. Refer to the TRACE Command on page 4-135 to determine the attributes
that can be combined with a TRACE command string.
SLSA 00065
Cause. You issued a TRACE command with a LOCKSIZE value that was greater than
the PAGES value.
Effect. SCF ignores the command.
Recovery. Retry the command with a LOCKSIZE value that is less than or equal to the
PAGES value. If PAGES is not specified, LOCKSIZE must be less than or equal to 64
pages.
SLSA 00066
Cause. The user issued an ABORT MON command against the monitor that is
running in the same CPU as the primary LANMAN. This action is not allowed because
LANMAN needs a local LANMON to function correctly.
Effect. SCF ignores the command.
Recovery. Issue the SWITCH PROCESS command, then retry the ABORT MON
command.
SLSA 00067
Cause. The user issued a SWITCH PROCESS command but the backup process has
no associated monitor process. This action is not allowed because LANMAN needs a
local LANMON to function correctly.
Effect. SCF ignores the command.
SLSA E000
64 Invalid TRACE command attribute combination
SLSA E00065 LOCKSIZE must be less than or equal to PAGES
SLSA E00066 Cannot stop objname because objname is running
in the same CPU as the primary LANMAN
SLSA E00067 Cannot switch $ZZLAN because the MON in the
backup CPU is STOPPED