Managing Software Changes (G06.24+)
What Is in an SPRNOTE
Managing Software Changes—427169-003
B-8
SPRNOTE Example
The installation database is now updated properly, and INSTALL
will later behave just as if you had continued with SYSGEN.
2. Manually replace and secure the SYSnn subvolume files
that are the target of this SPR:
a. > FUP
b. - VOLUME $SYSTEM.SYSnn
c. - INFO /OUT $S/ *
d. - RENAME FCHECK, PURGEME.*
e. - DUP $.ZUTIL.FCHECK, *, SOURCEDATE
f. - SECURE FCHECK, "< file's security from step c >"
Also RENAME, DUP, and SECURE the following files:
ISV filename
-------- --------
ZUTIL TANDUMP
ZUTIL FILCHECK
ZUTIL LKINFO
g. - LICENSE FCHECK
Also LICENSE the following files:
FILCHECK
LKINFO
h. - EXIT
3. a. Run the REPSUBSYS phase of INSTALL.
b. When INSTALL asks about updating USER ISVs, reply Y.
c. When INSTALL asks about updating TACL ISVs, reply S.
-------- OR --------
If you wish to produce a SIT (system image tape) containing
this SPR, perform the following steps instead of the above:
1. Run the SYSGEN phase of INSTALL.
2. Run the RESTSYS phase of INSTALL.
3. This SPR doesn't change TACLSEGF; before loading the system,
FUP DUP .TACLSEGF,.*
4. Perform a system load.
5. a. Run the REPSUBSYS phase of INSTALL.
b. When INSTALL asks about updating USER ISVs, reply Y.
c. When INSTALL asks about updating TACL ISVs, reply S.
- Perform these post-installation steps:
* If a system load was NOT performed:
1. If you used INSTALL, verify that all files in
$SYSTEM.PURGEME are closed, and when you are satisfied
that the new software works properly, purge them.
New Features: NONE
Problems Corrected:
1. [AAZ]
CAVEAT: This fix works only if T9053G07^AMH or later is
installed.
SYMPTOMS: CMFILE incorrectly reports data miscompare error.
CONDITIONS: Data blocks within a buffered file are newly created
and not yet written to disk, and corresponding disk areas