Managing Software Changes (G06.25+, H06.03+, J06.03+)
What Is in an SPR Note
Managing Software Changes—427169-005
B-7
SPR Note Example
Requisite SPRs: T1228AAG (If using SWAN 2)
T7953AAL (If using SWAN 2)
T9088ADQ
Required Hardware: NonStop S-series server
3880 ServerNet Wide Area Network
(SWAN) concentrator
(or)
3881 ServerNet Wide Area Network
(SWAN 2) concentrator
Required Firmware: T7953G01 SWAN FIRMWARE
Required Software: T1228G06 SWAN BASE (If using G06.13 or later)
T8365F40 WAN MANAGER (If using pre-G06.13)
T7925F40 WANMGR PM (If using pre-G06.13)
T7922F40 CONMGR (If using pre-G06.13)
T7909F40 WAN BOOT (If using pre-G06.13)
T7899F40 SCF/EXF PRD MOD
T9050G03 NONSTOP KERNEL
T9088G05 ENVOYACP/XF
T9338F40 CP6100
Manuals: NONE
NOTE: This SPR contains four downloadable modules for WANADCCP.
1. C8169P00 for RS232 and RS449 interface for SWAN.
2. C8169P20 for X.21 interface for SWAN.
3. C8169Q00 for RS232 and RS449 interface for SWAN 2.
4. C8169Q20 for X.21 interface for SWAN 2.
Installation Considerations:
Subsystem interruption required
Installation Instructions:
* When using DSM/SCM to install this SPR:
- RECEIVE the SPR from disk or tape.
- COPY the SPR to a new revision of the software configuration
that you want to update.
- BUILD and APPLY the configuration revision.
- Perform these pre-installation steps: NONE
- Run ZPHIRNM to perform the RENAME step.
- Perform these post-installation steps:
1. Use SCF to STOP or ABORT the lines using WANADCCP.
2. Use SCF to START the lines using WANADCCP.
New Features: NONE
Problems Corrected:
1. [AAN]
SYMPTOMS: A WANADCCP line occasionally reports error 164 to
an application's I/O requests.
CONDITIONS: A WANADCCP line configured with modifier "TWS" set
to "ON", modifier "Duplex" set to "FULL", and a valid
information or supervisory frame is received with the
Poll/Final bit set.
LIKELIHOOD: Likely