Measure Reference Manual
Current EOF 8192 B Maximum EOF 133693440 B
OSS Journal OFF SQL Journal OFF Percentage Used 0.00 %
• In Measure D-series and later PVUs, to show information about the currently active measurement
writing to OCT18:
+ STATUS MEASUREMENT OCT18
From 18 Oct 1994, 14:35:33
Cpu 1 Entities 46 Words
Disc 64 Entities 7552 Words
Current EOF 178 B Maximum EOF 1556480 B
Percentage Used 0.3 %
STOP MEASSUBSYS
The STOP MEASSUBSYS command stops all measurements and the subsystem processes.
Syntax
STOP [ MEASSUBSYS ]
MEASSUBSYS
is optional if you specified MEASSUBSYS as the default command object by using the ASSUME
command.
Related Commands
PageFunctionCommand
120Starts the Measure subsystemSTART MEASSUBSYS
127Determines whether any measurements are activeSTATUS MEASSUBSYS
Usage Notes
• The STOP MEASSUBSYS command can be executed only by a super-group user; that is, a
user who has user ID (255,*).
• If you enter this command interactively while measurements are active, MEASCOM warns
you about the measurements and asks you to confirm the command. If you enter this command
noninteractively or from a command (OBEY) file, MEASCOM stops the subsystem without
asking you for confirmation.
Example
To start MEASCOM, check the status of the Measure subsystem, then stop the subsystem:
11> MEASCOM
MEASURE Performance Monitor - T9086H06 - (01AUG11) - \SYSTEM
(C) Copyright 1986-2010 Hewlett-Packard Development Company, L.P.
1+ STATUS MEASSUBSYS
Number of Active (or Configured) Measurements = 0
Number of Active MEASCTL Processes = 4
in CPU(s): 0, 1, 2, 3
Number of Active MEASIP Processes = 4
in CPU(s): 0, 1, 2, 3
OSS OFF, SQL OFF, Skew copy time OFF, Lock CID table ON, CIDs = 64K/CPU
2+ STOP MEASSUBSYS
STOP MEASUREMENT
The STOP MEASUREMENT command stops the specified measurement.
130 MEASCOM Commands