Measure Reference Manual
Table 3 ZMS Style Format Error Field Values (continued)
MeaningValue
Subsystem version mismatch. The Measure PVU that formatted the record is earlier than that
of the instrumented product subsystem that produced this data record. There is more data
.<2>
in the internal record than MEASFH can format. Update the Measure PVU on the measured
system.
Template-version mismatch. The application requesting the data record is compiled with an
older version of MEASDDLS, or the structured data file was created with a record template
.<3>
older than the MEASFH version that produced the record. More data is available for reporting
but could not be passed in the interface. Update the application or convert the structured
data file to the new size.
Timer cell rendezvous failure..<4>
Reserved for future use..<5:11>
Timer cell allocation failure..<12>
ZMSPROC record only, USERDEF instrumentation for this process is delayed..<13>
ZMSPROC record only, SQL instrumentation for this process is delayed..<14>
ZMSPROC record only, OSSNS instrumentation for this process is delayed..<15>
Values of 0 or -1 indicate that there is data in the record. If you have older applications that
determine the presence of data by testing for 0, you might need to change those applications. For
example, test for a positive value, which indicates an error condition.
Table 4 Legacy Style Error Field Values
MeaningValue
No problem.0
Data record was not allocated because the maximum number of entries allowed under
concurrent measurement was exceeded.
1
Data record was not allocated because the maximum counter space allowed was exceeded.2
Entity was not measured because code sampling was already in progress. Applies to
PROCESSH entity type only.
3
Entity was not measured because of a MEASCTL internal error. The XPTR, an internal
addressing structure, could not be found.
4
Field overflowed in an accumulating or incrementing counter. The data record is written,
but the capacity of one or more 32-bit fields was exceeded. Accurate values are contained
in equivalent 64-bit fields. This is a warning, not an error.
65535
(G-series RVUs) Byte-count field overflow. The capacity of one or more 16-bit byte-count
fields has been exceeded. See the equivalent 32-bit fields for byte-count data. This is a
warning rather than an error. It applies to the DISC entity type only.
65534
Common Entity Header Fields
These fields appear in the header of all entity records and are defined once here instead of being
repeated in every entity description.
144 Entities and Counters