Measure Reference Manual
READLINKCACHE-ALL
Number of received messages for which both control and data bytes were cached in readlinkcache
buffers.
Counter type: Incrementing.
READLINKCACHE-CTRL
Number of received messages for which only control bytes were cached in readlinkcache buffers.
Counter type: Incrementing.
READLINKCACHE-NONE
Number of received messages for which neither control nor data bytes were cached in readlinkcache
buffers.
Counter type: Incrementing.
REPLYCTRLCACHE-MSGS
Number of message replies for which control was carried in the interrupt packet.
Counter type: Incrementing.
RESPONSE-TIME
Time that terminal processes in the CPU and in active measurements spent on terminal responses.
A transaction is a read from a terminal followed by a write to the terminal. Response time is the
interval between the end of the read and the beginning of the write.
PageFunctionRelated Counter
360Measures the number of transactionsTRANSACTIONS
360Measures response time and transactions for a particular
terminal
TERMINAL RESPONSE-TIME and
TRANSACTIONS
Counter type: Response time.
STARTING-FREE-CIDS
(ZMS Style only) Number of counter ID control blocks available for new counter records in this
processor at the beginning of the reported measurement interval.
Counter type: Snapshot.
STARTING-FREE-MEM
Number of free memory frames at the start of the measurement interval.
Counter type: Snapshot.
STARTING-SCL
Number of system process code and library segment frames allocated in physical memory at the
start of the measurement interval. This counter includes the number of frames allocated for TNS,
accelerated, and native code for system process code segments and the short address spaces
designated as system code (SC) and system library (SL). It also includes frames allocated for interrupt
procedures and millicode (for TNS/R systems).
Counter type: Snapshot.