RECORD device. FILE is "device" ENTRY-SEQUENCED.
.
.
.
(error, time items, and measurement identification items;
see Common Entity Header Fields (page 144))
.
.
.
* entity identification items:
02 pin type binary 16 unsigned.
02 device-name type character 8.
02 logical-device type binary 16 unsigned.
02 ctrl type binary 16 unsigned.
02 unit type binary 16 unsigned.
02 device-type type binary 16 unsigned.
02 device-subtype type binary 16 unsigned.
* counter value items:
02 requests type binary 32 unsigned.
02 read-busy-time type binary 64.
02 write-busy-time type binary 64.
02 reads type binary 32 unsigned.
02 writes type binary 32 unsigned.
02 input-bytes type binary 32 unsigned.
02 output-bytes type binary 32 unsigned.
* new entity identification item for D10:
02 channel type binary 16 unsigned.
02 servernet type binary 16 unsigned
redefines channel.
* F40 new entity identification items:
02 config-name type character 64.
02 adapter-name type character 64.
02 SAC-name type character 64.
02 GMS.
03 group type binary 32 unsigned.
03 module type binary 32 unsigned.
03 slot type binary 32 unsigned.
* F40 new counter value items:
02 read-qbusy-time type binary 64.
02 read-qtime type binary 64.
02 read-qlen-max type binary 16 unsigned.
02 write-qbusy-time type binary 64.
02 write-qtime type binary 64.
02 write-qlen-max type binary 16 unsigned.
02 device-qbusy-time type binary 64.
02 input-bytes-f type binary 64.
02 output-bytes-f type binary 64.
* New identifier in G05:
02 scsi-id type binary 64.
* New counters for G05:
02 dbio-reads type binary 32 unsigned.
02 dbio-writes type binary 32 unsigned.
end
For descriptions of the header fields used by all entities, see Common Entity Header Fields (page 144).
182 Entities and Counters