Measure Reference Manual

MEASFT 3262 (ERR_PARSE_SPLIT_TIME_WC): SPLIT, BY TIME * command not allowed.
MEASFT 3301 (ERR_CANNOT_SPLIT_BY_TIME): Only H01 and later data files can be
split by TIME, file version VNN.
MEASFT 4016 (ERR_NOMEMORY_TIME128): Not enough memory for TIME128 array,
bytes remaining = #nn.
New and Changed Information for H06.24/J06.13 RVUs (523324-016)
Revised information about active counter measurements in LISTACTIVE entity-type
(page 86), CPU (page 161), and PROCESS (page 291).
Revised OSS Journal Segment (page 149) to include information that if an OSS file is deleted
before the measurement ends, the translation may not be captured in the OSS journal.
Changed the RESERVED-1 field in the ZMSCPU-ID structure for the CPU entity to the FLAGS
field. Also added the definition for this new FLAGS (page 165) ID field.
Revised the description of CPU-BUSY-TIME (page 166) counter for the CPU entity on TNS/E
systems.
Added a new usage note to Usage Notes for J-Series CPU Entities (page 176) describing
Measure behavior when the number of enabled IPUs/CPU is dynamically increased during
a CPU measurement.
Changed the RESERVED-1 field in the ZMSPROC-ID structure for the PROCESS entity to the
FLAGS field. Also added the definition for this new FLAGS (page 297) ID field.
Added a new usage note to Usage Notes for J-Series PROCESS Entities (page 310) describing
Measure behavior when the number of enabled IPUs/CPU is dynamically increased during
a PROCESS measurement.
Definitions of the entity descriptors have been moved from MEASCONFIGURE (page 383) in
Chapter 4: Measure Callable Procedures to a new chapter, Chapter 5: Entity Descriptors
(page 451).
Added a new usage note to the Usage Notes (page 431) for MEAS_READACTIVE_MANY_
that clarifies the behavior resulting in an error 3402 (ERRM^CANNOTACCESS) and the
recommended response.
New and Changed Information for H06.23/J06.12 RVUs (523324-015)
Updated the Measure product versions to H06 and J04.
Note that the Measure H06/J04 PVU was initially released at the H06.22/J06.11 RVU,
however, no Measure Reference Manual updates were needed for the RVU.
Support for Partition Number for CLIM-attached Devices
Revised all Usage Notes and provided some examples for ADD, INFO, INFO MEASUREMENT,
LIST, LIST PLOT, and LISTALL commands in Chapter 2: MEASCOM Commands (page 35) to
indicate support for new partition parameter for CLIM-attached devices.
Revised LISTACTIVE Entity Specification Special Cases, DEVICE (page 89) and DISC (page 90)
to indicate differences in support for partition parameter and multiple names in the sac
parameter for CLIM-attached devices. DEVICE and DISC now each have a separate subsection.
DISC entity supports these new partition-related parameter changes; DEVICE entity does not.
Also, noted that DEVICE entity no longer supports path parameter.
Revised DEVICE (page 179) entity syntax and Usage Notes to indicate path parameter is no
longer supported.
New and Changed Information 21