Measure Reference Manual

select()fpathconf()FILE_GETINFO_
sockatmark()fstat()FILE_GETINFOBYNAME_
stat()fstatvfs()FILE_GETINFOLISTBYNAME_
statvfs()getpeername()FILEGETINFO_LIST
getsockname()DEVICEINFO
Counter type: Incrementing.
INITIAL-PRIORITY-END
(ZMS Style only) In H06.25/J06.14 and later RVUs, the target (requested) process priority in effect
at the end of the measurement interval. The initial priority specified for a process at the start of a
measurement can be changed during execution by using the ALTPRI TACL command, or the
ALTERPRIORITY, PRIORITY or PROCESS_SETINFO_ Guardian procedures. See also Usage Notes
for H-Series and J-Series PROCESS Entities (page 310).
Counter type: Snapshot.
INITIAL-PRIORITY-START
(ZMS Style only) In H06.25/J06.14 and later RVUs, the target (requested) process priority in effect
at the start of the measurement interval. The initial priority specified for a process at the start of a
measurement can be changed during execution by using the ALTPRI TACL command, or the
ALTERPRIORITY, PRIORITY or PROCESS_SETINFO_ Guardian procedures. See also Usage Notes
for H-Series and J-Series PROCESS Entities (page 310).
Counter type: Snapshot.
IPU-NUM
(ZMS Style only) In Measure H05/J03 and later PVUs, the number of the IPU on which the process
was executing when the sample was taken.
On a non-NSMA system, this field is always 0 (zero).
Counter type: Snapshot.
IPU-NUM-PREV
(ZMS Style only) In Measure H05/J03 and later PVUs, if an IPU switch took place during the
measurement interval, IPU-NUM-PREV displays number of the IPU on which the process was executing
before the most recent switch. If no IPU switch occurred during the measurement interval, this field
is not displayed.
On a non-NSMA system, this field is always 0 (zero).
Counter type: Snapshot.
IPU-SWITCHES
(ZMS Style only) Accumulating counter that indicates the total number of times that a process
switched IPUs while executing. On a non-NSMA system, this field is always 0 (zero).
In J06.07 and earlier RVUs, only DP2 processes showed valid values, while for all other processes
the field was reported as 0 (zero). In J06.08 and later RVUs, the field contains valid values for all
processes.
Counter type: Accumulating.
302 Entities and Counters