Measure Reference Manual

For RIPC records, GROUP and SLOT both have values of 0.
You can use the keywords GROUP, MODULE, REMOTE-CLUSTER, and SLOT in the IF and BY
clauses of the LIST and LISTALL commands.
NODE-CLASS
SAC type as defined in the system configuration database.
NODE-CLASS-S
Redefines NODE-CLASS as a four-character alphanumeric field. The possible values (blank filled
to four characters) are:
“CLIM”
“CLMI”
“CLMO”
“CLMS”
"COLO"
"ENET"
"IPC "
"MONT"
"NIOC"
"RIPC"
"SCSI"
"SWAN"
"* "
NOTE: CLIM is a wildcard for all CLIM node classes.
PF
(ZMS Style only) The structure that holds the port and fiber fields.
The port identifies a specific ServerNet connector within the ServerNet PIC
(or within the ServerNet Blade Switch on a NonStop BladeSystem) to which
the CLIM is connected.
PORT
(NonStop BladeSystems only.) The fiber identifies a specific connector within
the ServerNet cable to which the CLIM is connected.
FIBER
REMOTE-CPU
Number of the CPU on a remote ServerNet cluster with which the entity is communicating. Only
valid for RIPC. This field redefines subdevice in the DDL record.
SAC-NAME
Logical name of the SAC used in this path to the physical disk. Logical names are maintained by
the system configuration database. The name is null-filled and null-terminated.
For IPC records, Measure generates this identifier instead of a SAC name:
IPC-CPUxx-TO-CPUyy
where xx is the linker CPU number and yy is the listener CPU number.
328 Entities and Counters