Measure Reference Manual

Example 1 Using INFO Command to Determine When an Active Measurement Will Write Interval
Data
$DATA PERF 31> MEASCOM
MEASURE Performance Monitor - T9086J04 - (01FEB11) - \PROD1
(C) Copyright 1986-2010 Hewlett-Packard Development Company, L.P.
1+ STATUS MEASSUBSYS
Number of Active (or Configured) Measurements = 3
$DATA.PERF.MDFGUEST
$SYSTEM.MEASURE.DOFF3
$GUEST.USER1.MCPU
Number of Active MEASCTL Processes = 4
in CPU(s): 0, 1, 2, 3
Number of Active MEASIP Processes = 8
in CPU(s): 0, 1, 2, 3
OSS OFF, SQL OFF, Skew copy time OFF, Lock CID table ON, CIDs = 64K/CPU
2+ ADD MDFGUEST
3+ ADD $SYSTEM.MEASURE.DOFF3
4+ ADD $GUEST.USER1.MCPU
5+ INFO *
Add measurement $DATA.PERF.MDFGUEST
Data collected from system \PROD1, MEASURE release version H06.
From 13 Apr 2011, 14:00:57, Interval 10 Seconds
-- Add Disc $GUEST-M
Add measurement $SYSTEM.MEASURE.DOFF3
Data collected from system \PROD1, MEASURE release version H06.
From 7 Apr 2011, 8:52:59
Counter data records suppressed
-- Add Cpu *
-- Add Process *
-- Add File * (GUARDIAN)
-- Add Disc $*
-- Add Tmf *
-- Add Servernet * (*, *, 0, *, 0)
Add measurement $GUEST.USER1.MCPU -- Current Data File --
Data collected from system \PROD1, MEASURE release version H06.
From 13 Apr 2011, 11:55:35, Interval 10 Seconds
-- Add Cpu *
7+ EXIT
Considerations When Starting and Stopping Measurements 33