Measure Reference Manual
Recovery
Enter HELP error code number to determine the appropriate corrections, and retry the
operation. (For information on ALLOCATESEGMENT, see the Guardian Procedure Calls Reference
Manual.)
MEAS 3003
WARNING. Measurement was not stopped due to reason listed above.
Cause
The STOP MEASUREMENT command failed at some point during its processing.
Effect
The reason for failure is listed as an error returned from the callable procedures.
Recovery
Enter HELP error code number to determine the appropriate corrections, and retry the
operation. (For information on ALLOCATESEGMENT, see the Guardian Procedure Calls Reference
Manual.)
MEAS 3004
WARNING. Logging was not on so command had no effect.
Cause
LOG STOP was issued, but logging was not in effect.
Effect
The request is ignored.
Recovery
Informative message only; no corrective action needed.
MEAS 3005
WARNING. Changing current plot file to current data file.
Cause
ADD PLOT was issued, but the old data file associated with the plot was not the same as the
one just listed from the current data file.
Effect
The contents of the previous plot are lost.
Recovery
Informative message only; no corrective action needed.
MEAS 3006
WARNING. Volume not network-accessible with current system default.
Cause
A 7-character volume default was in effect with a remote system default.
Effect
All file names expanded with the current defaults are invalid.
Recovery
Change the system or volume default.
MEAS 3007
WARNING. No entities present to ADD; LIST records before trying ADD.
Cause
An ADD PLOT was performed without any records available to be added.
496 Error Messages