Measure Reference Manual
Effect
The request is ignored.
Recovery
Perform a LIST entity command to obtain a list of the desired records before trying to add to
the plot.
MEAS 3008
WARNING. Plot became full during ADD; there can be a maximum of 26
entities; some entities were not ADDed.
Cause
An attempt was made to add more than 26 items to a plot.
Effect
Some of the requested items were not added.
Recovery
Delete any unneeded items so there are 26 or fewer before adding the desired counters.
MEAS 3009
WARNING. Item not found -- item-name.
Cause
The indicated plot item was not found or, if the plot character was also used in the command
(for example, DELETE PLOT CPU-BUSY-TIME (A)), counter A was not an appropriate item name.
Effect
The requested operation is ignored.
Recovery
Check that you spelled the item correctly and entered the correct plot character.
MEAS 3010
WARNING. Measurement not found -- filename.
Cause
The indicated data file was not found.
Effect
The requested operation is ignored.
Recovery
Check that you spelled the file name correctly and that the indicated file was added.
MEAS 3011
WARNING. Counter not found -- counter-name.
Cause
The indicated counter was not found.
Effect
The requested operation is ignored.
Recovery
Check that you spelled the counter name correctly and that the indicated counter was added.
MEAS 3012
WARNING. Measfh option ignored; DELETE then ADD to change Measfh.
497